All demo datasets

Gas — Metro

Harbor City Gas (synthetic)
Sample data · no sign-up
Disclosure control Suppression k = 15 1 customer ≤ 15% complementary on

Restore industry minimums
Weather-sensitive
39.2%
heating-driven
Base load / month
907409
base consumption
Degree days
2329 HDD
2564 CDD
Fit quality (R²)
0.791
over 11 months

Consumption vs. degree days, by month

energy vs. °F·days

Each point is one month: total consumption against that month's heating + cooling degree days. A steeper rise means more weather-sensitive load.

The model

E = 907409 + 2241.2169·HDD + -740.0124·CDD

  • Heating slope: 2241.2169 / HDD
  • Cooling slope: -740.0124 / CDD
  • Weather-normalized annual: 14211222
Method: base-65°F degree days (US EIA / NOAA); degree-day regression (ASHRAE Guideline 14; LBNL PRISM).